All Rights Reserved. HARDWARE CONFIGURATION The FHL-7124 has two switches and two jumper blocks which are used to configure the board. These switches and jumpers are located as follows.
S1: PC I/O Base Address
Switch S1 sets the base PC I/O address for accessing the FHL-7124 adapter card. The following table lists the valid switch settings and the corresponding PC I/O base address.
position 1 2 3 4 i/o
address bit A8 A7 A6 A5 addr
on on on on 0200
on on on off 0220
on on off on 0240
on on off off 0260
on off on on 0280
on off on off 02A0
on off off on ----
on off off off ----
off on on on 0300
off on on off 0320
off on off on 0340
off on off off 0360
off off on on 0380
off off on off 03A0
off off off on ----
off off off off ----
S2 - PC MEMORY WINDOW ADDRESSES
Switch S2 sets the PC memory addresses for the two 16 kilobyte windows into the FHL-7124 memory. Positions 1-4 set the PC memory address for Window 0; positions 5-8 set the PC memory address for Window 1. The following table lists the valid switch settings and the corresponding PC segment addresses.
WINDOW 0 WINDOW 1 1 2 3 4 addr 5 6 7 8 addr on on on on C000 on on on on ---- off on on on C400 off on on on C400 on off on on C800 on off on on C800 off off on on CC00 off off on on CC00 on on off on D000 on on off on D000 off on off on D400 off on off on D400 on off off on D800 on off off on D800 off off off on ---- off off off on DC00 on on on off E000 on on on off ---- off on on off ---- off on on off E400 on off on off E800 on off on off ---- off off on off ---- off off on off EC00 on on off off ---- on on off off ---- off on off off ---- off on off off ---- on off off off ---- on off off off ---- off off off off ---- off off off off ----J1 - PC INTERRUPT REQUEST LEVEL This jumper selects the PC IRQ used when the board microcode wants to interrupt the PC. Choices are IRQ2, IRQ3, IRQ4, IRQ5, and IRQ7. A three position jumper selects an optional regulated +9 volt DC power source on one of two V.24/RS-232 pins. Installing the shunt on positions 1-2 enables this power source on V.24 pin 9, installing the shunt on positions 2-3 enables this power source on V.24 pin 25, removing the shunt disables this feature. The maximum current used should not exceed 0.5 amps.
PRIMARY CHANNEL
SIGNAL CIRCUIT PIN I/O
TXD 103 02 OUT
RXD 104 03 IN
RTS 105 04 OUT
CTS 106 05 IN
DSR 107 06 IN
DTR 108 20 OUT
DCD 109 08 IN
SCTE 113 24 OUT
TXC 114 15 IN
RXC 115 17 IN
RI 125 22 IN