All Rights Reserved. HARDWARE CONFIGURATION The FHL-7123 has one switch and five jumper blocks which are used to configure the board. These switches and jumpers are located as follows.
S1: PC I/O Base Address
Switch S1 sets the base PC I/O address for accessing the FHL-7123 adapter card. The following table lists the valid switch settings and the corresponding PC I/O base address.
position 1 2 3 4 i/o
address bit A8 A7 A6 A5 addr
on on on on 0200
on on on off 0220
on on off on 0240
on on off off 0260
on off on on 0280
on off on off 02A0
on off off on ----
on off off off ----
off on on on 0300
off on on off 0320
off on off on 0340
off on off off 0360
off off on on 0380
off off on off 03A0
off off off on ----
off off off off ----
position 5 6 i/o default serial
addr IRQ port
off off 03F8 4 COM1
off on 02F8 3 COM2
on off 03E8 4 COM3
on on 02E8 3 COM4
J1 - PC INTERRUPT REQUEST LEVEL
This jumper selects the PC IRQ used when the board microcode wants to interrupt the PC. Choices are IRQ2, IRQ3, IRQ4, IRQ5, and IRQ7. This jumper controls the enabling of the PC interrupt request level selected by jumper J1. When the shunt is installed on the top two pins the software can enable and disable the PC Interrupts. When the shunt is installed on the bottom two pins the PC interrupts are always enabled. This second option should be used with any software not supplied by Fraser's Hill. This jumper controls the enabling of DMA channel 1. When the shunt is installed on the top two pins the software can enable and disable DMA channel 1. When the shunt is installed on the bottom two pins DMA channel 1 is always enabled. This second option should be used with any software not supplied by Fraser's Hill. DMA channel 3 can only be enabled by the software. A three position jumper selects an optional regulated +9 volt DC power source on one of two V.24/RS-232 pins. Installing the shunt on positions 1-2 enables this power source on V.24 pin 9, installing the shunt on positions 2-3 enables this power source on V.24 pin 25, removing the shunt disables this feature. The maximum current used should not exceed 0.5 amps. When this shunt is installed the FHL-7123 asynchronous port will use the IRQ selected by J1 for the synchronous port instead of the default interrupt request level selected by switch S1 positions 5-6. When this shunt is not installed the asynchronous port will use the default interrupt request level for the serial port selected by switch S1 positions 5-6.
PRIMARY CHANNEL
SIGNAL CIRCUIT PIN I/O
TXD 103 02 OUT
RXD 104 03 IN
RTS 105 04 OUT
CTS 106 05 IN
DSR 107 06 IN
DTR 108 20 OUT
DCD 109 08 IN
SCTE 113 24 OUT
TXC 114 15 IN
RXC 115 17 IN
RI 125 22 IN